How Gleanvolt decides
You don’t need to read this page to use Gleanvolt. It explains why Gleanvolt does what it does, which helps when something looks surprising.
Gleanvolt only sets one thing
Section titled “Gleanvolt only sets one thing”Your inverter decides where electricity comes from and goes to. Your charger charges the car. Gleanvolt talks to both over your home network, and changes only:
- how much current the charger may give the car, from moment to moment, and when it starts and stops;
- whether the home battery may discharge, if you use the battery discharge hold.
Everything else, such as when the home battery charges or what goes to the grid, the inverter decides as it always has.
The surplus
Section titled “The surplus”Gleanvolt reads, every few seconds, what the panels make, what goes to or comes from the grid, what the home battery does, and what the car takes. From that it works out what the house uses, and the surplus:
surplus = what the panels make − what the house uses
The surplus is the power the car could take without buying from the grid or emptying the home battery. The solar modes give the car the surplus, and no more.
A passing cloud doesn’t stop a charge. Gleanvolt decides on the average of the last three minutes, and changes the current only in steps of at least one ampere.
The car’s minimum: why charging pauses
Section titled “The car’s minimum: why charging pauses”A car can’t charge on very little current. By the charging standard, the least is 6 A, which is about:
- 1.4 kW on one phase;
- 4.1 kW on three phases.
So on three phases, a surplus of 3 kW can’t charge the car at all. If Gleanvolt kept the charger on at 6 A, the missing 1.1 kW would come from the grid or the home battery. Instead, the solar modes pause the car, and continue when the surplus is enough again. A car that pauses and restarts a few times on a cloudy day is Gleanvolt working as intended.
The modes deal with this gap in different ways:
- Solar pauses.
- Forecasted may let the home battery lend the difference, on a day the forecast says it can pay back.
- Solar + grid and Targeted may buy the difference from the grid, so the sun that is there isn’t wasted.
A restarted charge runs for at least 10 minutes, and a paused one waits a while before it starts again, so the car isn’t switched on and off every few minutes.
Pausing and standing down
Section titled “Pausing and standing down”When a mode has to wait, it does one of two things:
- A short wait (under 15 minutes): the charger stays on, at 0 A. The car is paused.
- A longer wait, such as overnight or until the low tariff: the charger is switched to Stop. Gleanvolt calls this standing the charger down. When it’s time, the charger is switched back on.
The Overview says which, and until when.
The home battery
Section titled “The home battery”The home battery and the car both want the sun. Each mode settles that differently:
| Mode | The home battery |
|---|---|
| Solar | Filled first; the car waits |
| Forecasted | Gets the weak morning and evening sun, and is full by 19:00 |
| Solar + grid | Shares the sun with the car |
| Fast (no battery) | Kept out of the charge |
| Targeted | Keeps its priority; the car gets what the battery doesn’t need |
Why is the battery’s priority worth anything? In the evening, the battery runs your house from the sun you stored. Every kWh the car took from it during the day is a kWh you buy at night.
The forecast
Section titled “The forecast”With a Solcast account, Gleanvolt knows roughly how much sun is still to come today and tomorrow. Forecasted and Targeted use it to plan. Forecasts are wrong sometimes, so:
- Forecasted plans on a cautious estimate, not the most likely one, so that its promise, “the home battery is full by evening”, holds on most days.
- It compares the forecast with what the panels really make, and adjusts. If the forecast is far off, it stops trusting it for the rest of the day.
- Real sun always counts. A sunny moment the forecast missed still goes to the car.
The grid meter
Section titled “The grid meter”Everything above depends on the meter at your grid connection measuring all three phases. If it misses one, the surplus is wrong, and the solar modes may never start: see When the grid meter misses a phase.