Skip to content

Troubleshooting and FAQ

http://gleanvolt.local:8090 doesn’t open. Some phones and networks can’t find .local names: older Android phones, guest or IoT Wi-Fi networks, Linux without the nss-mdns package, Docker without --network host, and Windows when the firewall blocked Gleanvolt. Use the computer’s address instead, such as http://192.168.1.20:8090. Your router’s list of connected devices shows it.

It’s called gleanvolt-2.local. Another device already uses gleanvolt.local, usually a second Gleanvolt. That is expected.

The page doesn’t open at all, even by address. Check that Gleanvolt is running: see Is it running? below.

Every page goes to the setup wizard. Something required is still missing: the password, the inverter or the charger. Gleanvolt waits, and controls nothing, until they are set. Finish the setup wizard and press Restart on its last step.

I finished the wizard, but it still goes to the wizard. Gleanvolt hasn’t restarted since. On Windows nothing restarts it for you: close it and start it again.

I forgot the password. Click Forgot your password? on the sign-in page. You can reset it with the recovery key you saved during setup. If you don’t have the key, press Write a code on the machine: Gleanvolt writes a one-time code where only someone with access to the computer can read it.

Terminal window
sudo cat /var/lib/gleanvolt/password-reset-code.txt

The code works once, for 15 minutes.

The home battery level never changes, and solar and grid show 0. The inverter’s and the charger’s addresses are swapped. Both answer on the same port, so Gleanvolt connects to either. Swap them on Settings, save and restart.

Everything reads zero. Gleanvolt can’t reach the devices. Check the addresses on Settings, and that Modbus TCP is turned on.

The search says “port open, no Modbus reply”. Something else is connected to the device, such as Home Assistant’s integration, evcc, or a second Gleanvolt. Most devices accept only one connection. Stop the other one.

The house seems to use all the sun every afternoon, and no solar mode starts. Your grid meter may be missing a phase: see When the grid meter misses a phase.

The figures look wrong, rather than missing. Compare them with your inverter’s and charger’s own display or app, and keep charging Off until they agree. Report it, with your inverter’s and charger’s model, on GitHub.

The forecast is empty. Open Settings → Solar forecast: it says whether Solcast refused the key, didn’t know the site, or the day’s forecasts are used up. See Solar forecast.

Charges are listed under the wrong day. The time zone isn’t set. Set it on Settings (for example Europe/Prague), save and restart.

I pressed a mode, but the car doesn’t charge. Usually Gleanvolt is waiting, and the Overview’s sentence says for what: more sun, a full home battery (Solar), the low tariff, or the start time of a planned charge. Also check:

  • The car is plugged in, and its own charging isn’t scheduled or limited in the car’s app.
  • Nobody changed the charger on the wallbox or in its app. Gleanvolt then leaves it alone: start the mode again.

The car pauses and restarts on a cloudy day. That is expected: a car needs at least about 4.1 kW on three phases, and Gleanvolt pauses rather than buy the difference. See How Gleanvolt decides.

A charge I planned for the night didn’t happen. Gleanvolt was off when the departure passed, or for longer than 12 hours, so it didn’t resume the mode after starting again. Its log says why, in a line starting Not resuming after the restart.

Charging stopped and the mode is Off again. Every mode stops by itself when it’s done: the car is full or unplugged, the amount was delivered, the departure passed, or the day’s sun is over. The charge’s page under Sessions says why.

A charge pauses suddenly in the evening. A big appliance such as an electric oven can take several kilowatts at once, which leaves no surplus for the car. The House figure on the Overview shows it.

The battery discharge hold is on, but the battery still discharges a little. About 50–65 W is normal: the inverter’s own use. More than that means the hold didn’t take: look at the Overview’s Battery figure.

Open Settings → Health: Last poll should be a few seconds ago. If the page doesn’t open:

Terminal window
systemctl status gleanvolt
sudo systemctl start gleanvolt # if it was stopped

If someone pressed Stop service, Gleanvolt stays stopped on purpose until you start it.

Gleanvolt writes what it decided and why to a log, one file per day, kept for 14 days. If you report a problem, the log of that day helps most.

Installed with The log
Linux /var/log/gleanvolt/, or journalctl -u gleanvolt
Docker the logs folder, or docker logs gleanvolt-controller
NAS the logs folder in the folder you made for Gleanvolt
Windows the logs folder next to the program

A normal stop ends the log with a line saying stopped cleanly. A log that just ends, without that line, means Gleanvolt was killed: for example by a power cut, or the computer running out of memory.

Ask on GitHub. Say which inverter, charger and car you have, how you installed Gleanvolt, and what you expected to happen. Attach the log of that day, but check it first: it can contain your devices’ addresses.